APC SmartUPS RT 3000VA Extended-Length Runtime Double-Conversion Online Rackmount 3U UPS. (SURTA3000RMXL3U-US)

SURTA3000RMXL3U-US

Refurbished with new batteries

APC SmartUPS RT 3000VA Extended-Length Runtime Double-Conversion Online Rackmount 3U UPS.  (SURTA3000RMXL3U-US)

More details

In Stock

USD$1,259.99

Add to wishlist

Data sheet

Output watt capacity (watts)2100
Output volt amp capacity (VA)3000
Output Voltage (Volt)120V
Nominal Input Voltage (Volt)120V
Input Connector TypeNEMA 5-15P
Waveform TypeSine wave
Weight (lbs.)120
Height (inches)5.10
Width (inches)17
Depth (inches)26.00
Replacements Battery KitUBC44

More info

Output

  • Output Power Capacity 2100 Watts / 3000 VA
  • Nominal Output Voltage 120V
  • Waveform Type Sine wave
  • Output Connections
    • (6) NEMA 5-15R (Standard 3-prong receptacles)
    • (2) NEMA 5-20R (3-prong 20Amp receptacles. Can accept standard 3-prong 15Amp plugs)

Input

  • Nominal Input Voltage 120V
  • Input Frequency 50/60 Hz +/- 5 Hz (auto sensing)
  • Input Connections NEMA L5-30P (30 Amp Twistlock) Cord Length 8 feet (2.44 meters)
  • Input voltage range for main operations 90 - 150V

Batteries & Runtime

  • Included Battery Modules 2
  • Typical recharge time 2.50 hour(s)
  • Replacement Battery UBC44
  • Extended Runtime Battery Modules (EBM's) Available (Model SURT192RMXLBP)
  •  Runtime Chart

     

    (All times in minutes)

    UPS Only

    With 1 EBM

    With 2 EBM's

     

    With 3 EBM's

     

    With 4 EBM's

     

    Runtime at full load (2100 Watts)

    14

    57

    103

    151

    199

    Runtime at 75% load (1575 Watts)

    21

    79

    141

    206

    272

    Runtime at half load (1050 Watts)

    34

    122

    217

    315

    416

    Runtime at 25% load (525 Watts)

    72

    253

    437

    633

    850

    Runtime at minimal load (210 Watts)

    174

    589

    954

    N/A

    N/A

Communications & Management

  • Interface Port(s) DB-9 RS-232,Smart-Slot
  • Available SmartSlot™ Interface Quantity 1
  • Emergency Power Off (EPO) Yes

Surge Protection and Filtering

  • Surge energy rating 480 Joules
  • Filtering Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449

Physical

  • Height 5.10 inches (130 mm)
  • Width 17.00 inches (432 mm)
  • Depth 26.00 inches (660 mm)
  • Rack Height 3U
  • Net Weight 120.00 lbs. (54.55 kg)
  • Audible noise at 1 meter from surface of unit 55.00 dBA
  • Online Thermal Dissipation 655.00 BTU/hr

Conformance

  • Regulatory Approvals CSA,FCC Part 15 Class A,OSHPD,UL 1778
  • Environmental Compliance RoHS 7b Exemption