Viewed products

Newsletter

Please, Log-in to subscribe to newsletter.

Online only

APC 6000VA 6KVA RT Series Double-Conversion Rack/Tower UPS (SURT6000XLT-US) US Only

SURT6000XLT-US

Refurbished with new batteries

APC 6000VA 6KVA RT Series Double-Conversion Rack/Tower UPS with TMXR. Refurbished (SURT6000XLT-US) US Only

More details

In Stock

USD$2,239.99

Add to wishlist

Data sheet

Output watt capacity (watts)4200
Output volt amp capacity (VA)6000
Output Voltage (Volt)208
Nominal Input Voltage (Volt)208V
Input Connector TypeNEMA L6-20P
Waveform TypeSine wave
Weight (lbs.)140
Height (inches)6
Width (inches)17
Depth (inches)26
Replacements Battery KitUBC44

More info

This is a refurbished Uninterruptible Power Supply/Battery Backup unit.  All products sold by BatteryUPSforLESS are fully covered for all parts and labor by our famous One-Year "No-Hassle" warranty and our innovative 30-Day "Lemon" warranty.

 

Capable of supporting 6kVA in a 3U rack/tower convertible form, users can support power hungry blade servers or heavily loaded equipment racks. This flexible form factor allows standardization across multiple applications. High power internal chargers allow virtually unlimited additional matching battery packs to comply with aggressive runtime demands of business- systems.

Features

  • Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS overload condition or fault.
  • Scalable runtime Allows additional run time to be quickly added as needed.
  • Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced.
  • Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power.
  • Network manageable Monitor and control the UPS and access environmental information remotely via included PowerChute software or APCs Network Management Card with temperature monitoring.
  • Rack/Tower convertible Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
  • Flash-upgradeable firmware Easy implementation of new firmware upgrades.
  • User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR).
  • Disconnected battery notification Warns when a battery is not available to provide backup power.
  • Frequency and voltage regulation Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
  • Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances.
  • Input power factor correction Minimizes installation costs by enabling the use of smaller generators and cabling.
  • Generator compatible Ensures clean, uninterrupted power to the loads in the event of an extended power outage.
  • Cold-start capable Provides temporary battery power when the utility power is out.

Output

  • Output Power Capacity 4200 Watts / 6000 VA
  • Nominal Output Voltage 208V
  • Output Voltage Note Configurable for 208 or 240 nominal output voltage
  • Frequency (sync to mains) 50/60 Hz +/- 3 Hz
  • Waveform Type Sine wave
  • Output Connections
    • (2) NEMA L6-20R
    • (2) NEMA L6-30R

Input

  • Bypass Internal Bypass (Automatic and Manual)
  • Nominal Input Voltage 208V
  • Input Frequency 50/60 Hz +/- 5 Hz (auto sensing)
  • Input Connections NEMA L6-30P
  • Cord Length 10 feet (3.05 meters)
  • Input voltage range for main operations 160 - 280V
  • Input voltage adjustable range for mains operation 100 - 280V
  • Other Input Voltages 240

Batteries & Runtime

  • Included Battery Modules 2
  • Typical recharge time 2.50 hour(s)
  • Replacement battery cartridge UBC44 RBC Quantity 1 per module
  • Typical Backup Time at Half Load 15.8 minutes (2100 Watts)
  • Typical Backup Time at Full Load 5.3 minutes (4200 Watts)

Communications & Management

  • Interface Port(s) DB-25 RS-232,Smart-Slot
  • Pre-Installed SmartSlot Cards AP9619

Physical

  • Maximum Height 17.00 inches (432 mm)
  • Maximum Width 5.10 inches (130 mm)
  • Maximum depth 26.00 inches (660 mm)
  • Rack Height 3U
  • Net Weight 120.00 lbs. (54.55 kg)
  • Shipping Weight 140.00 lbs. (63.64 kg)
  • Audible noise at 1 meter from surface of unit 55 dBA
  • Online Thermal Dissipation 1040.00 BTU/hr

Conformance

Accessories and Compatible units

23 other products in the same category: